Free graph maker & data converters

Dose-Response Curve Maker (Hill Plot)

Linearise a sigmoidal dose-response curve with the Hill plot, fit a straight line and read the Hill coefficient and EC50 from its slope and intercept.

Your data
6 rows × 2 columns · tab-separated
Graph
−1.0−0.50.00.51.01.5−2.0−1.5−1.0−0.50.00.51.01.5log10 [dose]log10 (R / (100 - R))log10 (R / (100 - R))y = 1.201x − 0.4706, R2 = 0.9988
Hover over a point to read its value.
Statistics
SeriesnMeanMedianSDSEMinMax
log₁₀ (R / (100 - R))6-0.18417-0.1741.11960.45709-1.7291.295
SeriesModelEquationParametersR²
log₁₀ (R / (100 - R))lineary = 1.201x − 0.4706b = -0.47057, m = 1.20090.99879
Chart options
Y seriesError bars (±)

Units: m^2 → m², H_2O → H₂O, 10^{-3} → 10⁻³, \mu → μ, \deg → °

How to use the Dose-Response (Hill Plot)

  1. Express the response R as a percentage of the maximum response (0 to 100).
  2. For each dose calculate log₁₀(dose) and log₁₀(R / (100 − R)). Leave out responses at 0 and 100.
  3. Paste the two columns, or edit the sample, and keep the linear trendline.
  4. The slope is the Hill coefficient n. EC50 = 10^(−intercept / slope).

From a sigmoid to a straight line

Dose-response data usually follow a sigmoidal (S-shaped) curve on a log-dose axis: R = 100·[D]ⁿ / (EC50ⁿ + [D]ⁿ), where n is the Hill coefficient and EC50 is the dose giving half the maximum effect. Rearranging gives R / (100 − R) = ([D]/EC50)ⁿ, and taking logs: log₁₀(R / (100 − R)) = n·log₁₀[D] − n·log₁₀(EC50). That is a straight line in log dose with slope n. This is the Hill plot, a classic way to estimate n and EC50 without nonlinear software.

Worked example

The sample has responses at six doses from 0.1 to 30 µM, such as 55.8% at 3 µM and 95.2% at 30 µM. The Hill plot is a good straight line: log₁₀(R/(100−R)) = 1.201 × log₁₀(dose) − 0.4706, R² = 0.9988. The slope gives a Hill coefficient of 1.20 (mild positive cooperativity). EC50 = 10^(0.4706 / 1.201) = 10^0.392 = 2.47 µM, close to the 2.5 µM used to generate the data.

Dose (µM)Response (%)log doselog(R/(100−R))
0.11.8−1.000−1.729
0.38.4−0.523−1.039
126.20.000−0.450
355.80.4770.102
1083.91.0000.716
3095.21.4771.295

Accuracy and alternatives

The Hill plot is sensitive to the responses near 0% and 100%, where a small measurement error becomes a large change in log(R/(100−R)). Use only the points between roughly 10% and 90% for the fit, and be careful with the maximum: if the true maximum is not 100% of your scale the line bends. The standard modern method is a four-parameter logistic fit by nonlinear regression, which estimates the top, bottom, EC50 and slope together. Plotiq fits straight lines, polynomials, exponentials and power laws, not the four-parameter logistic, so use this plot for a quick estimate and check important results with dedicated fitting software.

To show the sigmoid itself, plot response against dose on a log X axis with the log graph maker.

Frequently asked questions

What is EC50?
The dose or concentration that produces half of the maximum response. It is the usual measure of a drug’s potency in a dose-response experiment.
What does the Hill coefficient mean?
It describes how steep the response is. n = 1 is a simple one-site response, n above 1 suggests cooperativity, and n below 1 suggests negative cooperativity or heterogeneity.
Can I fit a four-parameter logistic curve here?
Not directly. This page uses the Hill plot, which is a straight-line transformation. A four-parameter logistic needs nonlinear regression software.
Is my data private?
No. Your data never leaves your browser. Plotiq parses and plots files locally with JavaScript, so nothing is uploaded to a server.

Guides that go with this tool

Last updated: · by Dev Patel ·Read our guides