Free graph maker & data converters

Arrhenius Plot Maker

Plot ln k against 1/T, fit a straight line and read the activation energy from its slope. The sample data is already set up: replace it with your rate constants.

Your data
6 rows × 2 columns · tab-separated
Graph
2.42.62.83.03.23.412345671000 / T (K-1)ln kln ky = −6.038x + 21.48, R2 = 1.0000
Hover over a point to read its value.
Statistics
SeriesnMeanMedianSDSEMinMax
ln k64.0624.2231.88190.76831.3516.366
SeriesModelEquationParametersR²
ln klineary = −6.038x + 21.48b = 21.481, m = -6.03830.99995
Chart options
Y seriesError bars (±)

Units: m^2 → m², H_2O → H₂O, 10^{-3} → 10⁻³, \mu → μ, \deg → °

How to use the Arrhenius Plot

  1. Measure the rate constant k at several temperatures T in kelvin (at least five).
  2. Calculate 1000 / T and ln k for each and paste them as two columns, or edit the sample.
  3. Keep the linear trendline. The equation and R² appear in the legend.
  4. Multiply the slope by −R × 1000 to get the activation energy Eₐ in J/mol.

What an Arrhenius plot shows

The Arrhenius equation says that a reaction’s rate constant depends on temperature as k = A·e^(−Eₐ/RT), where Eₐ is the activation energy, R is the gas constant (8.314 J mol⁻¹ K⁻¹) and A is the pre-exponential factor. Taking natural logs gives ln k = ln A − (Eₐ/R)(1/T), which is a straight line when ln k is plotted against 1/T. The slope is −Eₐ/R and the intercept is ln A.

Plotting 1000/T instead of 1/T keeps the axis numbers readable (around 3 instead of 0.003), but remember the factor of 1000 when you calculate Eₐ from the slope.

Worked example: six temperatures

The sample data are rate constants at 300, 320, 340, 360, 380 and 400 K. A linear fit gives ln k = −6.038 × (1000/T) + 21.48 with R² = 0.99995. The slope in the units of the plot is −6.038 per 1000 K⁻¹, so Eₐ = 6.038 × 1000 × 8.314 = 50,200 J/mol, about 50 kJ/mol. The intercept gives ln A = 21.48, so A ≈ 2.1 × 10⁹ s⁻¹.

T (K)k (s⁻¹)1000/Tln k
3003.863.3331.351
32013.53.1252.603
34041.72.9413.730
3601122.7784.716
3802722.6325.606
4005822.5006.366

Common mistakes

Use kelvin, not Celsius; with Celsius the plot is not a straight line. Use the natural logarithm for ln k (not log₁₀) unless you adjust the constant by 2.303. Do not forget the minus sign: Eₐ is positive when the slope is negative. A curved Arrhenius plot is informative rather than wrong: it can mean a change of mechanism with temperature or a measurement problem at one end. With only two temperatures, a line always fits perfectly and you have no check on it, so measure at least five.

To see the numbers behind the line, the line of best fit calculator shows the slope with its standard error, which gives you an uncertainty on Eₐ.

Frequently asked questions

How do I find activation energy from an Arrhenius plot?
Fit a straight line to ln k against 1/T. Then Eₐ = −slope × R. If you plotted 1000/T, multiply by 1000 as well.
Why plot ln k against 1/T?
Because that turns the exponential Arrhenius equation into a straight line, so the slope and intercept can be read directly.
Can I use degrees Celsius?
No. The equation requires absolute temperature in kelvin: add 273.15 to Celsius values first.
Is my data private?
No. Your data never leaves your browser. Plotiq parses and plots files locally with JavaScript, so nothing is uploaded to a server.

Last updated: · by Dev Patel ·Read our guides