Free graph maker & data converters

Beer's Law Plot Maker

Plot absorbance against concentration for your standard solutions, fit a straight line and calculate the molar absorptivity from its slope.

Your data
6 rows × 2 columns · tab-separated
Graph
010203040500.00.10.20.30.40.50.60.70.8Concentration (μ M)AbsorbanceAbsorbancey = 0.01501x + 0.002143, R2 = 1.0000
Hover over a point to read its value.
Statistics
SeriesnMeanMedianSDSEMinMax
Absorbance60.37750.37750.28090.114680.0040.754
SeriesModelEquationParametersR²
Absorbancelineary = 0.01501x + 0.002143b = 0.0021429, m = 0.0150140.99997
Chart options
Y seriesError bars (±)

Units: m^2 → m², H_2O → H₂O, 10^{-3} → 10⁻³, \mu → μ, \deg → °

How to use the Beer's Law Plot

  1. Measure the absorbance of standards of known concentration at one wavelength.
  2. Paste concentration in the first column and absorbance in the second, or edit the sample.
  3. Keep the linear trendline. The slope is the absorbance per unit concentration.
  4. Divide the slope by the path length (usually 1 cm) to get ε.

The Beer–Lambert law

The Beer–Lambert law states that absorbance A = ε·c·l, where ε is the molar absorptivity (L mol⁻¹ cm⁻¹), c is the concentration (mol/L) and l is the path length of the cuvette (cm). At a fixed wavelength and path length, absorbance is proportional to concentration, so a plot of A against c is a straight line through (or close to) the origin, with slope ε·l.

Worked example: six standards from 0 to 50 µM

The sample absorbances rise from 0.004 for the blank to 0.754 for the 50 µM standard. The fit is A = 0.01501 × c + 0.0021 (c in µM) with R² = 0.99997. The slope is 0.01501 absorbance units per µM, which is 15,010 per mol/L, so for a 1 cm cuvette ε ≈ 1.50 × 10⁴ L mol⁻¹ cm⁻¹. An unknown that reads 0.400 corresponds to (0.400 − 0.0021) / 0.01501 = 26.5 µM.

Concentration (µM)01020304050
Absorbance0.0040.1500.3030.4520.6020.754

When Beer’s law fails

The law holds for dilute solutions. At high concentration the points bend below the line because of molecular interactions and stray light in the instrument. As a rule, keep absorbance readings between about 0.1 and 1.0, and dilute any sample above that. Different wavelengths, scattering from particles, and chemical equilibria such as dimerisation also cause departures. If your top points fall away from the line, leave them out of the fit and report the linear range. For quantifying unknowns with detection limits, use the calibration curve calculator, and see the calibration curve guide for the full method.

Frequently asked questions

How do I find molar absorptivity from a Beer’s law plot?
Divide the slope (absorbance per mol/L) by the path length in cm. If concentration is in µM, multiply the slope by 10⁶ first.
Should the Beer’s law line go through zero?
Ideally yes, within the noise. A large intercept suggests a blank or baseline problem. Fit the intercept rather than forcing it.
Why does my line curve at high concentration?
Beer’s law holds only for dilute solutions. Above an absorbance of about 1, instrument stray light and molecular interactions bend the curve.
Is my data private?
No. Your data never leaves your browser. Plotiq parses and plots files locally with JavaScript, so nothing is uploaded to a server.

Last updated: · by Dev Patel ·Read our guides